[BH-1787] Reboot to MSC endpoint To allow the automation of gathering logs and swapping out OS images during tests a MSC reboot endpoint was added. Together with a change to ecoboot, this allows the sending of a "reboot to MSC" command. The deivce will then reboot and enter MSC mode.
[BH-1791] Add CPU frequency lock during log dump This will improve security and peripheral stabilization when downloading logs to a file.
[BH-1801] Fix incorrect calculation of requested CPU frequency Sometimes when the frequency is locked, e.g. at 132 MHz, the algorithm still calculated a lower frequency, e.g. 66 MHz.
[BH-1688] Create a standard for logs * Adding document describing how to use logger * Adjusting logs to follow a new guide * Change order in log header: line number is now before function name
[BH-1774] Fix frequency lock during user activity - Sentinel locks the frequency when pressing buttons and the encoder. - The "user activity" sentinel will be properly managed by the system (CpuGovernor) just like other sentinels. - Adding information about active sentinels in the power management statistics logs
[MOS-1011] Fix frequency switching stability Multiple fixes of clock switching related stability issues: * added RC oscillator hysteresis as in NXP example; * changed DCDC converter config; * configure PLL2 to be able to run on any CPU frequency level; * added switching to 1.275V (overdrive) voltage when applying any clock change above 12MHz as well as LDO or bandgap switching, as done in Mbed OS' lpm.c for RT1050; * changed BMCR AXI queues weighs for SDRAM in JLink scripts to disable operations reordering, as it is known to cause data integrity issues; * extracted some code to separate files; * smaller or bigger code cleanups.
[BH-1412] Whitelist update Whitelist removed for Harmony Changed the way whitelist is obtained Added missing logs for Eink Dispaly
[BH-1412] Fix system shutdown procedure Changed startup services order. Prevent handling multiple "close ready" messages from one service while closing system. Introduced a new state in ServiceGUI. Fixed a problem with turning on Harmony with a connected USB cable.
[BH-1412] Fix services dependencies Changes in dependecy managment Replacing state flags with states in ServiceGUI Unifying some parts of code
[BH-1412] Improve system shutdown procedure Changed default Worker join timeout to a more realistic value in case of system shutdown procedure.
[MOS-30] Fix for Alarm not being handled properly during a phone call During the phone call, the alarm was not displayed and subsequent alarms after this scenario did not work. This has now been fixed and the alarm during a phone call will be automatically snooze.
[BH-1722] Fix unswitchable alarm audio Disabling the alarm by clicking "deep press" on the system shutdown screen only visually deactivated the alarm but the alarm sound continued to ring.
[MOS-183] Fix RT1051 debug build Fix of multiple issues that resulted in debug build failing.
[BH-1624] Fix shutdown procedure In some cases, the system wasn't able to turn off because the GUI service got stuck. The device was still working in the background. The cause was an empty queue in DrawCommandQueue which hang the GUI worker. The interface was modified and synchronization mechanism was removed. The thread no longer waits in dequeue(). Also changed the worker to close in the right way the logger worker.
[BH-1639] Add welcome message with charging info Add new bell welcome window Add new close reasons Add new actions Bump assets version Remove bold text from welcome message Remove bold text from onboarding popups
[MOS-903] Remove reboot to USB MSC mode Remove mechanics enabling to perform reboot to MSC mode by sending request to one of the endpoints via serial port, as it is not implemented in bootloader and may potentially be unsafe.
[MOS-237] Removed unnecessary workaround for system reboot Removed workaround for rebooting into recovery (update)
[MOS-882] Fix FLAC file playback with USB cable connected Fix of the issue that caused system crash when trying to play 96kHz FLAC file with USB cable connected. The reason of the issue was the lack of FreeRTOS heap space left, what caused pvPortMalloc() to fail when allocating memory for stream buffer. Additionally minor code cleanup.
[MOS-851] Remove factory reset screen from backup and restore Fix of the issue that factory reset screen informing user of need to manually turn on the phone to continue the process was appearing also when restarting to backup or restore.
[MOS-786] A/B Booting - fixed factory reset from menu Now factory reset works both from ecoboot and from menu